APQ 80/540 Chromatic Focal Shift
APQ 80/540 UV–VIS–SWIR Polychromat Chromatic Focal Shift
2 / 8
APQ 80/540 Matrix Spot Diagram
APQ 80/540 UV–VIS–SWIR Polychromat Matrix Spot Diagram
3 / 8
APQ 80/540 Geometric MTF vs. Field
APQ 80/540 UV–VIS–SWIR Polychromat Geometric MTF vs. Field
4 / 8
APQ 80/540 Transverse Ray Fan
APQ 80/540 UV–VIS–SWIR Polychromat Transverse Ray Fan
5 / 8
APQ 80/540 RMS Spot Radius vs. Field
APQ 80/540 UV–VIS–SWIR Polychromat RMS Spot Radius vs. Field
6 / 8
APQ 80/540 Field Curvature / Distortion
APQ 80/540 UV–VIS–SWIR Polychromat Field Curvature / Distortion
7 / 8
APQ 80/540 Polychromatic FFT PSF
APQ 80/540 UV–VIS–SWIR Polychromat Polychromatic FFT PSF
8 / 8
APQ 80/540 Optical Path Difference
APQ 80/540 UV–VIS–SWIR Polychromat Optical Path Difference

APQ 80/540 UV–VIS–SWIR WF Polychromat

APQ 80/540 UV–VIS–SWIR WF Polychromat

365–2500 nm UV–VIS–NIR–SWIR
80 mm / 540 mm / f/6.75
4.55° full unvignetted field
Unvignetted image circle approx. Ø 42.9 mm
Polychromatic Strehl (Huygens) 0.997

Price
on request

Lead time
on request

Inquiry


  • Description
  • Specification
  • Optical Design Evaluation
  • Applications

APQ 80/540 UV–VIS–SWIR WF Polychromat

The APQ 80/540 UV–VIS–SWIR WF Polychromat combines a 80 mm clear aperture and 540 mm focal length with f/6.75 and a 4.55° full unvignetted field.

The optical system is continuously corrected over 365–2500 nm in a common image plane. The resulting unvignetted image circle is approximately Ø 42.9 mm.

This combination of broadband polychromatic correction, fast focal ratio and large unvignetted field is intended for demanding astronomical, scientific, remote-sensing and optronic imaging tasks.

Matched Teledyne detector

For use of the SWIR range to 2.5 µm, the Teledyne CHROMA-A is particularly well matched: 1280 × 480 pixels at 30 µm pitch provide an active area of 38.4 × 14.4 mm and a diagonal of approximately 41.0 mm. This nearly fills the approximately Ø 42.9 mm unvignetted image circle. CHROMA-A covers 380–2500 nm; a separate UV channel or detector is required for the 365–380 nm portion.

Optical type
UV–VIS–SWIR WF Polychromat

Clear aperture
80 mm

Focal length
540 mm

F-number
f/6.75

Spectral range
365–2500 nm

full unvignetted field
4.55° (±2.275°)

Unvignetted image circle
Ø 42.9 mm

Suitable Teledyne detector
Teledyne CHROMA-A, 1280 × 480 pixels, 30 µm pitch, 38.4 × 14.4 mm active area, approx. 41.0 mm diagonal, 380–2500 nm

Back focus
230 mm

Evaluated wavelengths
12: 365, 404.7, 486.1, 546.1, 632.8, 656.3, 852.1, 1014, 1128.6, 1529.6, 1970.1, 2500 nm

Maximum chromatic focal shift
15.467 µm

Diffraction-limited focus range
99.508 µm

Polychromatic Strehl (Huygens)
0.997

Airy radius (primary wavelength)
4.5 µm

Field curvature sagittal
-0.0081 mm

Field curvature tangential
-0.0351 mm

Optical Design Evaluation

APQ 80/540 Chromatic Focal Shift
APQ 80/540 Chromatic Focal Shift
APQ 80/540 Matrix Spot Diagram
APQ 80/540 Matrix Spot Diagram

APQ 80/540 Geometric MTF vs. Field
APQ 80/540 Geometric MTF vs. Field
APQ 80/540 Transverse Ray Fan
APQ 80/540 Transverse Ray Fan

APQ 80/540 RMS Spot Radius vs. Field
APQ 80/540 RMS Spot Radius vs. Field
APQ 80/540 Field Curvature / Distortion
APQ 80/540 Field Curvature / Distortion

APQ 80/540 Polychromatic FFT PSF
APQ 80/540 Polychromatic FFT PSF
APQ 80/540 Optical Path Difference
APQ 80/540 Optical Path Difference

Teledyne detector example: Teledyne CHROMA-A

The sensor format is matched to the unvignetted image circle so that the selected Teledyne FPA can use the available field without edge vignetting while exploiting the SWIR range to 2.5 µm.

Astronomy and wide-field imaging

Large unvignetted fields support survey imaging, extended celestial objects, mosaics and large-format detectors while preserving broadband correction.

Satellite observation and remote sensing

The wide field and short focal length support rapid acquisition of large sky and object fields, including satellite observation, SSA/SDA/SST and multispectral remote sensing.

Defense, security and optronics; science and industry

The broadband corrected image plane supports sensor testing, calibration, material and process observation, scientific imaging and customer-specific multisensor systems.